Labour Day Special Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: geek65

DES-1121 Specialist: Implementation Engineer - PowerMax and VMAX Family Solutions Exam Questions and Answers

Questions 4

An array has reached its capacity m the Storage Resource Pool (SRP). What is the function of the SRP Reserved Capacity?

Options:

A.

Accommodate new host writes

B.

Accommodate SRDF/A delta sets

C.

Provide space for snapshot deltas

D.

Provide space for snapshot copies

Buy Now
Questions 5

From an application perspective what should be done prior to performing an SRDF Fallback operation?

Options:

A.

Continue accessing the R2 devices

Start accessing the R1 devices before running the command

B.

Stop accessing the R2 devices

Run the command and then start accessing the R1 devices

C.

Stop accessing the R2 devices

Start accessing the R1 devices before running the command

D.

Continue accessing the R2 devices

Run the command and then start accessing the R1 devices

Buy Now
Questions 6

An administrator is using Unisphere tor PowerMax Workload Planner to assess the performance and compliance of a PowerMax Storage Group (SG) How does the Planner calculate if the Storage Group workload is stable?

Options:

A.

Both calculated values are within a 10-15% threshold of the SL-defined response time

B.

Both calculated values are within the SL-defined response time

C.

One of the calculated values remains within the SL-defined response time

D.

One of the calculated values is within 10-20% of the SL-defined response time

Buy Now
Questions 7

An SRDF/Metro pair was created with vWitness After a network outage, the administrator discovers that the SRDF pair is in an ActiveBias state What is the correct sequence of events to bring the SRDF pair into an ActiveActive state?

Options:

Buy Now
Questions 8

Production work has been started on the R2 devices after an 5RDF Failover operation. Where will the changes made to the R2 devices be reflected in the SRDF Query output shown in the exhibit?

Options:

A.

1

B.

2

C.

3

D.

4

Buy Now
Questions 9

Which units of measure are used to specify the size type when creating volumes in Unisphere?

Options:

A.

Cylinders, MB, GB, TB

B.

MB and GB only

C.

MB, TB, PB

D.

Cylinders, GB, TB. PB

Buy Now
Questions 10

A systems administrator asks whether their host is supported for non-disruptive migration (NDM) between PowerMax arrays. The host they plan to migrate has one HBA and no multipathing software. What information should be provided to the administrator?

Options:

A.

Install Solutions Enabler on the host

B.

NDM is supported for the host

C.

Upgrade to the latest host HBA driver version

D.

NDM is not supported for the host

Buy Now
Exam Code: DES-1121
Exam Name: Specialist: Implementation Engineer - PowerMax and VMAX Family Solutions Exam
Last Update: May 7, 2024
Questions: 69
DES-1121 pdf

DES-1121 PDF

$28  $80
DES-1121 Engine

DES-1121 Testing Engine

$33.25  $95
DES-1121 PDF + Engine

DES-1121 PDF + Testing Engine

$45.5  $130