Black Friday Early Access - 75% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: save75geek

NS0-094 NetApp Hardware Support Engineer Professional Exam Questions and Answers

Questions 4

During an ONTAP upgrade, nodeA1 fails to boot. You notice that it is loading the previous version of ONTAP software. What step can be taken to boot the node successfully?

Options:

A.

From the loader prompt of nodeA1, use setenv GX_PRIMARY_KERNEL_URL to point to the correct version of ONTAP software.

B.

From the loader prompt of nodeA1, run boot_backup to run the correct version of ONTAP software.

C.

From the clustershell of the partner, run system node image modify to point to the correct version of ONTAP software.

D.

From the clustershell of nodeA1, run system node image modify to point to the correct version of ONTAP software.

Buy Now
Questions 5

A customer has a 4-node NetApp ONTAP cluster. There are two SVMs on the cluster. One SVM serves NFS home directories, and the other SVM serves SMB shares. Each SVM has one LIF per node using a dedicated port. The NFS SVM LIF is homed on port e1c, and the SMB SVM LIF is homed on port e2c on each node.

All ports and LIFs share the same layer 2 network in the same broadcast domain. There is a requirement that in the event of a physical port failure, NFS and SMB data must never share the same physical port.

Which action meets the requirement?

Options:

A.

Create DNS delegation records and modify the network interfaces to listen for a DNS query.

B.

Create new failover groups and modify the network interfaces failover group.

C.

Create a new IPspace and move the broadcast domain to the new IPspace.

D.

Configure the SVMs and data LIFs for host-name resolution using an external DNS server.

Buy Now
Questions 6

You are replacing a boot device on a FAS8300 system that is running ONTAP 9.10P6 software. You attach a USB memory stick to the external USB port on the storage controller but cannot access the memory stick.

What step needs to be performed to access the boot device?

Options:

A.

Set the port to “enabled” with setenv.

B.

You need to use ONTAP 9.11 or later software.

C.

Add the boot device before the BIOS is loaded.

D.

The external USB port is not activated on NetApp systems.

Buy Now
Questions 7

What should be the first step taken after detecting a NetApp WAFL inconsistency?

Options:

A.

Run wafliron.

B.

Stabilize the system.

C.

Force offline the affected aggregate.

D.

Run a dump to null.

Buy Now
Questions 8

During a new SVM deployment, all of the FC LIFs are showing an admin/oper status of up/down. The LIF extended status is Waiting for Link.

What is causing this status?

Options:

A.

The FC cables are bad.

B.

The sync-destination LIF is in switchover state.

C.

NPIV is disabled on the switch.

D.

The switch fabric is not configured.

Buy Now
Questions 9

In a SAS stack of shelves, what is the topology of the connection between expander and disk?

Options:

A.

arbritrated loop

B.

point-to-point

C.

loop

D.

ring

Buy Now
Questions 10

Users are reporting slowness when accessing certain volumes with extremely high-performance requirements via NFSv3 on a four-node switched NetApp ONTAP cluster. Other volumes on the same cluster are behaving normally. Investigation reveals that there is a high amount of throughput recorded for the cluster LIFs.

What action enables you to determine which volumes are affected?

Options:

A.

View the active CIFS sessions on the cluster to determine the affected workloads.

B.

Check the NFS file locking lease period for the affected volumes.

C.

Review NFS export policies to ensure that client subnets are listed for the affected volumes.

D.

View the NFS connected client information and review the “Remote-Reqs” counter.

Buy Now
Questions 11

You are troubleshooting an L2 connectivity problem, and you want to analyze network traffic.

Which command do you use to capture network packets?

Options:

A.

traceroute

B.

netstat

C.

ping

D.

tcpdump

Buy Now
Questions 12

Which two factors can increase the chances of experiencing a NetApp WAFL inconsistency on an aggregate? (Choose two.)

Options:

A.

ignoring NetApp Active IQ health risks

B.

constantly running at high load

C.

using outdated disk firmware

D.

upgrading frequently

Buy Now
Questions 13

While reviewing a fresh install of a new NetApp ONTAP HA pair, the Field Support engineer notices that the controllers do not report the same system storage configuration.

The first controller reports the following:

System Storage Configuration: Multi-Path HA

The second controller reports the following:

System Storage Configuration: Single-Path HA

There are no EMS errors, and there are no alerts on the system or on NetApp ONTAP System Manager.

What is the next step in troubleshooting this issue?

Options:

A.

Ensure that the second controller is set up for ADP.

B.

Ensure that all disk shelves are connected, with at least four SAS cables to each controller.

C.

Reboot the controller that is reporting the single-path configuration.

D.

Check cabling to the controller that is reporting the single-path configuration.

Buy Now
Questions 14

How do you set environment variables to factory settings?

Options:

A.

set-defaults

B.

unsetenv all

C.

setenv factory

D.

wipeconfig

Buy Now
Questions 15

Which LOADER prompt command ensures that POST is done on boot?

Options:

A.

setenv POST=true

B.

bye

C.

boot_diag

D.

boot_ontap

Buy Now
Questions 16

A 4-node NetApp ONTAP cluster sent an alert that one of the cluster interconnect switches has failed. After replacement, the system administrator notices that half of the cluster LIFs are not on their home ports.

Which parameter must the system administrator enable to automatically migrate the cluster LIFs?

Options:

A.

failover-policy

B.

auto-revert

C.

allow-lb-migrate

D.

home-port

Buy Now
Questions 17

Which two NetApp tools should be used when troubleshooting the root cause of an unexpected controller reboot? (Choose two.)

Options:

A.

Active IQ Unified Manager

B.

Active IQ Digital Advisor

C.

ONTAP CLI

D.

ONTAP Mediator

E.

Active IQ Config Advisor

Buy Now
Questions 18

A node has unexpectedly failed and is unresponsive through its node management interface.

Which two commands from the Service Processor are helpful to determine the root cause? (Choose two.)

Options:

A.

sp status –d

B.

event log show

C.

system log

D.

system core

Buy Now
Questions 19

Which two statements are correct when describing L1 and L2 Watch Dog Resets (WDR)? (Choose two.)

Options:

A.

L2 WDR requests creation of a core dump before reset.

B.

L1 WDR is initiated after 0.5 seconds from the event.

C.

L1 WDR performs a soft reset.

D.

L2 WDR is initiated after 2 seconds from the event.

Buy Now
Questions 20

Which two tools can you use to invoke AutoSupport? (Choose two.)

Options:

A.

NetApp Cloud Insights

B.

CLI

C.

the NetApp Active IQ website

D.

the SmartSolve tool

Buy Now
Questions 21

Which type of core file is generated when a node panics?

Options:

A.

mgwd core

B.

user space core

C.

sync core

D.

kernel core

Buy Now
Questions 22

You are reviewing the output of disk show and one of the disks is reporting a container type of “unknown”.

What is causing this status?

Options:

A.

The disk is not owned by a member of the high-availability (HA) pair.

B.

The disk is failed.

C.

The disk is in the maintenance center.

D.

The disk does not have an owner.

Buy Now
Questions 23

Which of the following scenarios could result in a NetApp WAFL inconsistency in a RAID DP aggregate?

Options:

A.

two disks failing and a block error during reconstruction

B.

rebooting a node during a disk reconstruction

C.

two disks failing within seconds of each other

D.

both party disks failing

Buy Now
Questions 24

While performing a health check on a cluster, you notice the following entries in the cluster event log:

Referring to the exhibit, which of the following actions do you take?

Options:

A.

Sanitize the disk.

B.

Reseat the disk.

C.

Review the current firmware and known issues.

D.

Use diskcopy to copy the disk to a working spare.

Buy Now
Exam Code: NS0-094
Exam Name: NetApp Hardware Support Engineer Professional Exam
Last Update: Nov 21, 2026
Questions: 81
NS0-094 pdf

NS0-094 PDF

$22.5  $89.99
NS0-094 Engine

NS0-094 Testing Engine

$28.75  $114.99
NS0-094 PDF + Engine

NS0-094 PDF + Testing Engine

$35  $139.99