ITFAS-Level-1 Inspection and Testing of Fire Alarm Systems Level I Exam Questions and Answers

Questions 4

What is the maximum travel distance between two fire alarm boxes measured horizontally on the same floor?

Options:

A.

30 feet (9.1 meters)

B.

60 feet (18.3 meters)

C.

90 feet (27 meters)

D.

200 feet (61 meters)

Buy Now
Questions 5

A single open fault, in a Class A pathway, shall result in the annunciation of which of the following signals?

Options:

A.

Alarm

B.

Pre-alarm

C.

Supervisory

D.

Trouble

Buy Now
Questions 6

Which three of the following are how a McCulloh transmitter should be inspected? (Choose three.)

Options:

A.

Distinct waterflow condition

B.

Physical condition

C.

System normal condition

D.

Verify location

Buy Now
Questions 7

Which two of the following are needed to perform a periodic test of a projected beam type smoke detector? (Choose two.)

Options:

A.

Blocking the transmitter

B.

Introducing smoke

C.

Using a listed test switch

D.

Using an optical filter

Buy Now
Questions 8

What is the maximum extended interval allowed for equipment to get inspected?

Options:

A.

3 months

B.

6 months

C.

12 months

D.

18 months

Buy Now
Questions 9

Which NFPA standard regulates how to perform the test of engine driven generator?

Options:

A.

NFPA 70

B.

NFPA 72

C.

NFPA 101

D.

NFPA 110

Buy Now
Questions 10

The fire alarm control unit shows a supervisory signal on the display. What is the possible cause?

Options:

A.

A duct smoke detector is in alarm.

B.

A manual fire alarm box has been activated.

C.

A spot smoke detector is in alarm.

D.

A waterflow alarm has been activated.

Buy Now
Questions 11

Records of inspections, testing, and maintenance shall be provided in accordance with which section of NFPA 72?

Options:

A.

7.6.6

B.

7.8.2

C.

10.5.3

D.

14.6.3

Buy Now
Questions 12

When the main power is disconnected, how long should a power supply with emergency voice communication systems work in alarm mode?

Options:

A.

Maximum of 5 minutes

B.

Maximum of 15 minutes

C.

Minimum of 5 minutes

D.

Minimum of 15 minutes

Buy Now
Questions 13

When testing initiating devices, what is the maximum allowed time for the supervising station to verify receipt of the signal?

Options:

A.

60 seconds

B.

80 seconds

C.

90 seconds

D.

120 seconds

Buy Now
Questions 14

What must be done if the frequency of sensitivity testing is extended to 5 years?

Options:

A.

Detectors must be from the same manufacturer.

B.

Detectors must be located in the same area.

C.

Records of nuisance alarms shall be maintained.

D.

Records of serial numbers shall be maintained.

Buy Now
Questions 15

Smoke alarms in one- and two-family dwellings shall be replaced when they fail to operate or they have been in place a maximum of how many years?

Options:

A.

5

B.

6

C.

10

D.

12

Buy Now
Questions 16

Secondary power for the fire alarm primary power supply shall be tested under which load?

Options:

A.

Half load

B.

Maximum load

C.

Minimum load

D.

Supervisory load

Buy Now
Questions 17

Which three of the following are types of fire alarm control units? (Choose three.)

Options:

A.

Central station

B.

Dedicated function

C.

Protected premises

D.

Releasing service

Buy Now
Questions 18

Which of the following options is required while conducting annual testing of an audiovisual device?

Options:

A.

Confirm sound level based on design

B.

Confirm voice intelligibility

C.

Verify proper operation

D.

Verify proper setting of candela rating

Buy Now
Questions 19

How often should radio transmitters be inspected?

Options:

A.

Monthly

B.

Quarterly

C.

Semiannually

D.

Annually

Buy Now
Questions 20

Which two of the following should occur when a signal silence switch for a notification alarm is activated? (Choose two.)

Options:

A.

Audible appliances are deactivated.

B.

Door holders are deactivated.

C.

HVAC shutdown is deactivated.

D.

Visible appliances are deactivated.

Buy Now
Questions 21

According to NFPA 72, manual fire alarm boxes shall be located within which distance of each exit doorway on each floor?

Options:

A.

5 feet (1.5 meters)

B.

6 feet (2.0 meters)

C.

16 feet (5.0 meters)

D.

33 feet (10.0 meters)

Buy Now
Questions 22

After the secondary power supply has operated the fire alarm system under quiescent load,the secondary power shall be capable of operating all alarm notification appliances for which length of time?

Options:

A.

5 minutes

B.

10 minutes

C.

1 hour

D.

24 hours

Buy Now
Questions 23

The flash rate of visible notification appliances shall be a minimum of how many flashes per second?

Options:

A.

1

B.

2

C.

3

D.

4

Buy Now
Questions 24

Within a fire alarm control unit, what is the maximum delay in seconds for alarm system responses after the initiation device has been activated?

Options:

A.

10

B.

15

C.

30

D.

60

Buy Now
Questions 25

Which of the following situations is considered an impairment?

Options:

A.

Closed sprinkler valve

B.

Intelligible audibility

C.

Smoke detector within 4 feet of a return air opening

D.

Smoke detector within 4 feet of an air supply diffuser

Buy Now
Exam Code: ITFAS-Level-1
Exam Name: Inspection and Testing of Fire Alarm Systems Level I Exam
Last Update: May 9, 2025
Questions: 85