The humidity in the computer room has increased from about 60% up to 85% Relative Humidity (RH). What potential risk does this pose to your equipment?
An air-conditioner unit needs to be selected. Two types are available:
Unit-A has a Sensible Heat Ratio (SHR) of 0.7.
Unit-B has a Sensible Heat Ratio (SHR) of 0.9.
From an efficiency point of view, which one should be selected?
The building in which the computer room is housed is required to have a sprinkler system. The building is therefore equipped with a wet pipe system.
What action, if any, should you recommend for the computer room?
It is assumed that EMF shielding material must be installed as the EMF levels coming from the transformer room into the computer room are measured at 100mG. The transformer room is approximately 10 meters away from the computer room and is separated by a corridor. You can assume that no physical issues are present for installing shielding material at any area/location.
Where should you recommend the shielding material to be installed?
What is the floor loading requirement for a Rated-3 data center according to ANSI/TIA-942?
What should be implemented when an Inergen-based fire suppression system is installed in the computer room?
When designing a data center network, your company wants to minimize the number of network switches to manage.
What type of physical cabling layout would be the best choice?
What is a potential disadvantage of using a hypoxic-based fire suppression system as a fire extinguishing system?
A battery bank has 800 Ah total capacity. How much charging current should the rectifier be able to supply?
Racks with 1.0 m depth and cold aisle containment with 3 perforated tiles are used. What aisle pitch is recommended?
The noise levels in the data center are approximately 91 dB (A).
Do employers need to take precautions?
A sprinkler system employs automatic sprinklers attached to a piping system containing water and connected to a water supply so that water discharges immediately when a head opens. What is this called?
The building requires sprinklers and is equipped with a wet-pipe system. What action should you recommend for the computer room?
In order to save energy, you are going to install an automated system to switch off lights. What should be taken into consideration when installing such a system?
What is the minimum requirement for power feeds to a Rated-4 data center (ANSI/TIA-942)?
The computer room has high levels of H2S gas contamination. What is the best option to resolve this issue?
A computer room is fitted with a hypoxic-based fire suppression system. On what principle does it work?
What is the risk of high levels of hydrogen sulfide (H₂S) in the computer room?
What is a potential disadvantage of using water mist as a fire extinguishing system?
The humidity in the computer room has changed from about 50% down to 35% Relative Humidity (RH).
What influence does this have on Electrostatic Discharge (ESD)?
Smoke sensors must be installed in the computer room. What is the minimum density?
A data center is located in an area where the demand for power is higher than the utility power company is able to deliver. This results in frequent power outages and, therefore, power shedding (scheduled/controlled power shutdown for areas) is frequently applied. The mains power is more than 650 hours/year not available.
What type of generators should be installed?
When installing a raised floor, can we use a spirit level bar to level the floor?
The 'maximum exposed area' of the fire-rated glass is defined by the supplier as 3 sqm/32 sqft. The window area is 4 sqm/43 sqft.
What would be the best option?
A data center requires an audit for ANSI/TIA-942 Rated-3 compliance. Will the network architecture be part of this audit?