Summer Special Limited Time 65% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: geek65

1z0-902 Oracle Exadata Database Machine X9M Implementation Essentials Questions and Answers

Questions 4

How is Exadata Secure RDMA Fabric isolation used in X9M-2 with virtualization enabled?

Options:

A.

With Secure Fabric isolation, each Storage Server runs multiple KVM guests each dedicated to a Database VM cluster using a dedicated network partition and VLAN ID. This provides security and isolation between multiple tenants or VM clusters.

B.

With Secure Fabric isolation, each Database VM Guest uses a dedicated network partition and VLAN ID for client networking between application servers. This improves security by preventing man in the middle attacks.

C.

With Secure Fabric isolation, each Database VM Cluster uses a dedicated network partition and VLAN ID for Data Guard networking between the primary and disaster recovery Exadata racks. This improves security by isolating data guard traffic onto an encrypted network between data centers.

D.

With Secure Fabric isolation, each Database VM cluster uses a dedicated network partition and VLAN ID for cluster networking between the database servers in the VM Cluster. This provides security and isolation between multiple tenants or VM clusters.

Buy Now
Questions 5

You plan to monitor the status of the motherboard, memory, power, fans, and network cards on the database nodes in your Exadata Database Machine using Enterprise Manager.

Where must you set the thresholds for these hardware components and why, to assure that sensor readings, faults, and any related alerts, are visible in Enterprise Manager?

Options:

A.

No thresholds need to be set because they are preset in the ILOM and in Enterprise Manager

B.

Set thresholds in ILOM and in Enterprise Manager because they are not preset anywhere and must be set in both places.

C.

Set thresholds only in ILOM because they are not preset anywhere but need to be set only in ILOM.

D.

No thresholds need to be set because they are preset in the ILOM and these are sufficient for monitoring.

Buy Now
Questions 6

You must drop all celldisks on all the storage servers in an X9M-2 quarter rack as part of a reconfiguration project.

Which three statements describe the account on the storage servers which you should use and the tool that may be used to drop the celldisks?

Options:

A.

to the CELLADMIN account by calling CELLCLI on all cells using DCLI

B.

to an administrator-created storage server user with appropriate privileges on celldisk objects by calling CELLCLI on all cells using exadcli

C.

to the CELLMONITOR account using cellcli interactively on each storage server

D.

to an administrator-created storage server user with appropriate privileges on celldisk objects by calling EXACLI on all cells using exadcli

E.

to the CELLMONITOR account calling CELLCLI on all cells using DCLI

F.

to the CELLADMIN account using cellcli interactively on each storage server

Buy Now
Questions 7

Which two options describe the flash memory capabilities of the Exadata X9M-2 database and storage severs?

Options:

A.

4 x 6.4 TB NVMe flash cards on the High Capacity (HC) storage server

B.

4 x 6.4 TB NVMe flash cards on the database server

C.

8x 6.4 TB NVMe flash cards on the Extended (XT) storage server

D.

No flash storage on the database server

E.

8 x 6.4 TB NVMe flash cards on the Extreme Flash (EF) storage server

Buy Now
Questions 8

What type of SRs does the ASR Manager generate for Exadata?

Options:

A.

hardware assets

B.

backup and restore failures

C.

operating system components

D.

data entry errors

E.

software assets

Buy Now
Questions 9

Which two activities are supported on the storage servers in an Exadata Database Machine?

Options:

A.

changing the root password

B.

upgrading a device driver for hard disks when inserting a replacement disk after a hard disk failure

C.

installing an alternative package manager

D.

upgrading the Storage Server software package using rpm

E.

configuring secure shell user equivalency for the cellmonitor user

Buy Now
Questions 10

In order two support a new application, you are planning to add a RAC VM cluster to an existing Oracle Exadata X9M-2 deployment.

Which two methods can be considered?

Options:

A.

Use Oracle VM Manager.

B.

Use the OEDA web-based configuration tool.

C.

Use domu_maker utility.

D.

Use the xm command.

E.

Use the OEDA Command line interface.

Buy Now
Questions 11

Which four actions should you take before proceeding with applying updates to your Exadata Database Machine?

Options:

A.

Consult My Oracle Support note 888828.1 to determine the current recommended Exadata software release.

B.

Check the Exadata Critical Issues My Oracle Support note 1270094.1 for any issues not added to the latest version of exachk.

C.

Run exachk and resolve only WARNINGS that you have not seen before.

D.

Run the appropriate patchmgr preqequisite check step for each component being updated.

E.

Run patchmgr --all_comp —autofix —autobackup —upgrade —rolling.

F.

For database servers, perform a server backup using patchmgr —dbnodes db_list_file —backup —rolling.

Buy Now
Questions 12

Your customer needs to ensure that their data is available on the Exadata machine during updates. The customer wants to be able to update one server at a time but still be protected against single-node server failure.

What ASM redundancy level should they use?

Options:

A.

Normal

B.

Sparse

C.

High

D.

External

E.

Extended

Buy Now
Questions 13

An Exadata storage server physical disk on an X9M-2 high-capacity full rack entered the predictive failure state. Which two steps must you perform to replace this failed physical disk?

Options:

A.

Replace the failed physical disk.

B.

Add the griddisks back into the ASM diskgroup they used to be a member of.

C.

Identify the griddisks located on the failed physical disk and drop them from the associated ASM diskgroups.

D.

Rebalance the data on the effected griddisks before performing a manual drop command.

E.

Create a new celldisk and new griddisks on the replaced physical disk.

F.

Verify that the griddisks located on the physical disk have been successfully dropped from the associated ASM diskgroups.

Buy Now
Questions 14

Which two of the following network connection types can be deployed on the client network ports of an Exadata X9M-2 Database Server?

Options:

A.

2x 25Gb ports on eth1 and eth2 using SFP28 transceivers and OM4 fiber cable for backup network, and 2x 25Gb ports on eth5 and eth6 using

SFP28 transceivers and OM4 fiber cable for client network

B.

2x 25Gb ports on eth1 and eth2 using SFP28 transceivers and OM4 fibre cable for client network, and 2x 10Gb ports on eth9 and eth10 using RJ45 cat6 cable for backup network

C.

2x 10Gb ports on eth1 and eth2 using FU45 cat6 cable for client network, and 2x 25Gb ports on eth11 and eth12 using SFP28 transceivers and OM4 fiber cable for backup network

D.

2x 25Gb ports on eth1 and eth2 using SFP28 transceivers and OM4 fiber cable for backup network, and 2x 10Gb ports on eth3 and eth4 using RJ45 cat6 cable for client network

Buy Now
Questions 15

Which two options can be used to identify a damaged or failing flash card on an X9M-2 Database Machine High Capacity storage server?

Options:

A.

using the CELLCLI CALIBRATE command on the storage server after logging in as the celladmin user

B.

using the CELLCLI CALIBRATE command on the storage server after logging in as the root user

C.

hardware monitoring using the storage server ILOM

D.

using the CELLCLI list LUN DETAIL command as the celladmin user

Buy Now
Questions 16

You are working on a remote Exadata Database Machine with current software and firmware. You now need to start a storage server after hardware maintenance.

Which ILOM command starts the storage server?

Options:

A.

-> start /System

B.

-> start /SP/console

C.

-> set /SYS power_state=ON

D.

You must be physically present in the data center to start an Exadata Storage Server.

E.

-> start /SYSTEM/power

F.

-> start /SYS/power

Buy Now
Questions 17

What does the following command do?

root@rul6 -]# for j in {01..23} ; do ipmitool sunoem cli "set /SP/network/test ping=192.168.1.1$j'' ; done

Options:

A.

Sets the address for each storage and database server's /SP during installation to enable ping testing from the management network, run from the first database server.

B.

Verifies that the ILOM management network is working before installation of all storage and database servers in a full rack Exadata X9M-2, run from the first database server.

C.

Verifies that the ILOM management network is working after OEDA configuration has completed for all storage and database servers in a full rack Exadata X9M-2, run from the first database server.

D.

Sets the test address for the RoCE network for all storage and database servers in a full rack Exadata X9M-2, run from the first database server.

Buy Now
Questions 18

Which three component faults are covered by Oracle Auto Service Request (ASR)?

Options:

A.

Proactive recommendations for firmware

B.

Fan trays

C.

System Controller (SC)

D.

I/O boards

E.

RoCE network interface cards

F.

File system unmounted

Buy Now
Questions 19

Which of the below is NOT a precaution that should be adhered to in order to ensure the site is safe and ready for

Options:

A.

Do not use a flathead screwdriver to disconnect connector locks on LAN cables.

B.

Be sure that each grounding wire used for Oracle Exadata Rack is used exclusively for Oracle Exadata Rack.

C.

Do not install Oracle Exadata Rack near a photocopy machine.

D.

Do not place anything on top of Oracle Exadata Rack.

E.

When using shared grounding, the grounding resistance must not be greater than 10 ohms.

F.

Do not install Oracle Exadata Rack in a location that is exposed to direct sunlight.

Buy Now
Questions 20

Which two statements are correct about adding an additional database server to a physical Exadata X9M Database Machine using Oracle Exadata Deployment Assistant (OEDA)?

Options:

A.

Do not proceed if the OEDA Validate Configuration File step displays an error message about missing files p6880880.zip.

B.

Executing /opt/oracle.supportTools/reclaimdisks.sh -free -reclaim on each Exadata X9M Database server is required to reclaim disk space and perform partition reconfiguration.

C.

In order to configure the servers with Oracle Exadata Deployment Assistant (OEDA), the new server information must be entered in OEDA, and the configuration file must contain existing nodes.

D.

The applyElasticConfig.sh script performs network configuration for the new servers. The new servers are restarted at the end of the process.

E.

It is required to install OEDA on the first new database server.

Buy Now
Questions 21

Which three statements are true concerning the configuration or use of Enterprise Manager Cloud Control to monitor and manage Exadata Database Machine components?

Options:

A.

Cloud Control cannot monitor partitioned Exadata Database Machine systems.

B.

Storage nodes forward their SNMP traps to the Management Server process on the same storage node.

C.

Compute nodes forward their SNMP traps to the Management Server process on the same compute node.

D.

Cloud Control can monitor and manage a Database Machine storage Expansion rack.

E.

Oracle management agents must only be installed on one compute node in a Database Machine to enable monitoring and management of all compute nodes and storage nodes.

F.

Oracle management agents must only be installed on one storage node in a Database Machine to enable monitoring and management of all storage node.

Buy Now
Questions 22

Which two statements are true about Auto Service Request (ASR) with an Exadata Database Machine?

Options:

A.

ASR Manager must be installed and configured on a dedicated server external to the Database Machine.

B.

Configuring ASR is mandatory for all Database Machine assets.

C.

ASR Manager must be installed and configured on one of the database servers.

D.

ASR can upload configuration metadata to support problem resolution.

E.

ASR Manager opens a service request (SR) automatically after sensors detect hardware faults.

F.

ASR communicates with Oracle support services using HTTPS.

Buy Now
Questions 23

Which statement is true about the Persistent Memory Commit Accelerator?

Options:

A.

Persistent Memory Commit Accelerator tracks changes to Persistent Memory Data Accelerator to ensure duplicate blocks are not written to Flash.

B.

Persistent Memory Commit Accelerator helps to further reduce redo log write latency by using Persistent Memory and Remote Direct Memory Access (RDMA).

C.

Persistent Memory Commit Accelerator copies redo log data from disk for faster redo apply on Data Guard Standby Databases.

D.

Persistent Memory Commit Accelerator contains logging information from all tiers of the software stack for rapid triage and diagnostics.

E.

Persistent Memory Commit Accelerator reduces redo log write latency by using Persistent Memory and RDMA before flushing to Flash then disk.

Buy Now
Questions 24

Which are two correct statements for managing virtual deployment using Oracle Exadata Deployment Assistant (OEDA)?

Options:

A.

OEDA allows customers to have both bare metal (BM) and virtual machine (VM) in an Exadata X9M Quarter Rack.

B.

There is no limit on the number of VMs in an Exadata rack as long as the Exadata rack has adequate resources.

C.

OEDA deployment steps include calibrate cells, create cell disks, and resecure machine.

D.

OEDA sets up key-based authentication for the root user by using the setuprootssh.sh utility included with OEDA.

Buy Now
Questions 25

Which two statements are true about the types of Exadata X9M-2 storage servers: the High Capacity (HC) storage server, the Extreme Flash (EF) storage server and the Extended server?

Options:

A.

The HC storage server contains 12 x 18 TB hard disks, 4 x 6.4 TB PCIe flash cards, and 1.5 TB Persistent Memory.

B.

The XT storage server is an all-disk storage server with no flash, containing 12 x 18 TB hard disks, and 1.5 TB Persistent Memory.

C.

The EF storage server contains 8 x 6.4 TB PCIe flash cards.

D.

The EF storage server contains 8 x 6.4 TB PCIe flash cards and 756 GB Persistent Memory.

E.

The EF storage server contains 8 x 6.4 TB PCIe flash cards, and can be upgraded with 4 more for a total of 12.

Buy Now
Exam Code: 1z0-902
Exam Name: Oracle Exadata Database Machine X9M Implementation Essentials
Last Update: Jun 15, 2025
Questions: 85
1z0-902 pdf

1z0-902 PDF

$29.75  $84.99
1z0-902 Engine

1z0-902 Testing Engine

$35  $99.99
1z0-902 PDF + Engine

1z0-902 PDF + Testing Engine

$47.25  $134.99