Weekend Sale 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: clap70

H13-624_V5.5 HCIP-Storage V5.5 Questions and Answers

Questions 4

An Internet customer has deployed a remote replication environment based on multiple flash storage devices. During actual service running, the customer discovers that there are multiple running statuses for a remote replication pair. Which of the following statements is true about the running status of a pair?

Options:

A.

After a pair is disconnected, if the pair is deleted from the primary or secondary site, which causes configuration inconsistency between the primary and secondary sites, the pair running status changes to "To be recovered."

B.

When the pair running status is "Split," the pair relationship between the primary and secondary LUNs is interrupted (not manually).

C.

When the pair running status is "Normal," data synchronization between the primary and secondary LUNs is complete.

D.

When the pair running status is "To be synchronized," the pair relationship between the primary and secondary LUNs must be manually disconnected to meet the service requirements of a single LUN.

Buy Now
Questions 5

A bank customer purchases several Huawei flash storage devices to store upper-layer Oracle database service data. If an Oracle database fault occurs, engineers need to collect Oracle alert log files to locate the fault. Which of the following commands cannot be used to query the alert log path?

Options:

A.

ioscan -funC disk > /home/pvlinks_disk

B.

CRS_HOME/bin/diagcollection.sh

C.

show parameter background_dump_dest

D.

db2support outpath -d db_name -c

Buy Now
Questions 6

After a remote replication consistency group is created, if one remote replication task is faulty, other tasks in the consistency group run normally without waiting for the faulty task to recover.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 7

Assume a financial customer purchased multiple Huawei OceanStor Dorado 18000 storage devices to carry service data. A Fibre Channel link exception occurred in the storage environment. Which of the following are possible causes for this exception?

Options:

A.

When a switch network is used, the configured rate of the Fibre Channel host port does not match that of the switch.

B.

The optical fiber is poorly connected or faulty.

C.

The optical module rate of host ports does not match that of front-end storage ports.

D.

The IP address of the service network port on the application server is incorrectly set.

Buy Now
Questions 8

Assume an enterprise customer purchased several Huawei flash storage devices for service deployment. An engineer needs to configure Syslog notification on the storage system. Which of the following statements are false about configuration operations?

Options:

A.

During the configuration, the engineer needs to configure the SNMP protocol and USM users in the storage system for receiving and querying system alarms.

B.

To view the display format of Syslog content, the engineer can run the "show notification syslog" command.

C.

To change the display format of Syslog content to CEF, the engineer can run the "change syslog-notification format_type=cef" command.

D.

If certificates and CA certificates are generated on the Syslog server, the engineer does not need to perform any operation in the storage system.

Buy Now
Questions 9

In Huawei flash storage, the integrated I/O stack of SAN and NAS can be divided into the storage pool layer, space management layer, and data service layer. Which of the following are performance concerns of the space management layer?

Options:

A.

Cache hit ratio of hot metadata

B.

CPU usage of metadata background management

C.

Whether failover is enabled for protocol receiving threads

D.

Hit ratio of the prefetch algorithm

Buy Now
Questions 10

An engineer can use the ______ tool to install software for Huawei storage systems. This tool can collect and evaluate storage compatibility information in one-stop mode and supports batch installation of the UltraPath software, improving the software installation efficiency.

Options:

Buy Now
Questions 11

Similar to the alarm analysis method, the replacement method can be used to locate and rectify any type of faults for Huawei converged storage, and has no special requirement for maintenance personnel.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 12

In Huawei all-flash storage, the SmartDedupe and SmartCompression features reduce redundant data space consumption and improve the transmission and storage efficiency of a storage system. Which of the following statements about the features is false?

Options:

A.

Post-process compression means that data is first written to storage media and then read for compression.

B.

During inline deduplication, the system divides data into blocks and then calculates fingerprints for the blocks.

C.

During similarity-based deduplication in the background, the system does not divide data into blocks and can directly calculate similar fingerprints.

D.

Backup storage supports deduplication and compression of file systems.

Buy Now
Questions 13

An engineer can use multiple common management software to configure, manage, and maintain Huawei converged storage. Which of the following statements is false about the software and corresponding functions?

Options:

A.

SmartKit provides capabilities such as alarm reporting, file upload, and remote access.

B.

DeviceManager allows the engineer to allocate storage resources, manage users, manage data protection features, monitor device performance, and manage alarms.

C.

DME IQ enables cloud-based management, remote maintenance, automatic service request creation, and prediction and prevention, comprehensively improving customers’ O&M capabilities.

D.

The command-line interface (CLI) allows the engineer to allocate storage resources, manage users, manage data protection features, monitor device performance, and manage alarms.

Buy Now
Questions 14

When delivering a Huawei OceanStor Pacific storage project, a Huawei engineer vigorously promoted the SmartEncryption feature of scale-out storage to customers. Which of the following statements is false about this feature?

Options:

A.

When the data is read using the DPC or NFS protocol, the SED obtains the identity authentication key from the key management server, reads and decrypts the ciphertext data, and then returns the plaintext data to the protocol layer. The protocol layer returns the plaintext data to client applications.

B.

This feature supports encrypted data write using NFS, CIFS, HDFS, or S3. Data is decrypted and read using NFS, CIFS, HDFS, or S3.

C.

The file service client can write plaintext data through the NFS/CIFS/DPC protocol.

D.

Huawei OceanStor Pacific series scale-out storage supports disk encryption. All data delivered by services is stored on self-encrypting disks (SEDs).

Buy Now
Questions 15

An industry customer has purchased several Huawei flash storage devices for service deployment. An engineer wants to configure the HyperSnap feature on the storage devices. However, during the configuration, the engineer discovers that snapshots cannot be created for an existing protection group. The possible cause is that the storage pool where the source LUNs in the protection group reside has no available capacity.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 16

The scale-out storage system supports cabinet-level security. That is, N data blocks and M parity blocks are stored in different cabinets. If M nodes or M disks are faulty, the system can still read and write data without service interruption or data loss. If M cabinets are faulty, services may be interrupted.

Options:

A.

TRUE

B.

FALSE

Buy Now
Questions 17

SPC certification is a SAN performance test benchmark for third-party evaluation. Which of the following statements is true about SPC certification scenarios?

Options:

A.

SPC-2 applies to scenarios where random small I/Os are quickly responded.

B.

SPC-1 applies to scenarios of sequential large I/O access.

C.

SPC-2 applies to scenarios of sequential large I/O access.

D.

SPC-2 is used to test the SAN array performance in the OLPT, database, and email application scenarios.

Buy Now
Questions 18

During routine inspection, an engineer of a bank finds that an interface module of a Huawei flash storage device is faulty. In this case, the engineer can directly remove and insert the interface module without any pre-operations.

Options:

A.

TRUE

B.

FALSE

Buy Now
Exam Code: H13-624_V5.5
Exam Name: HCIP-Storage V5.5
Last Update: Jun 14, 2025
Questions: 60
H13-624_V5.5 pdf

H13-624_V5.5 PDF

$25.5  $84.99
H13-624_V5.5 Engine

H13-624_V5.5 Testing Engine

$30  $99.99
H13-624_V5.5 PDF + Engine

H13-624_V5.5 PDF + Testing Engine

$40.5  $134.99